SonicOS Enhanced 5.6.5.1 Release Notes
P/N 232-002002-00 Rev B
Symptom
Condition / Workaround
Issue
Traffic over static VPN routes is dropped
after a node level link failover.
Occurs after the X1 link on the Master node is
disconnected. Traffic will drop over the VPN tunnel,
but after flushing the connection, traffic will
recommence flowing through the tunnel.
90215
Active/Active clustering IP Helper support
does not yet exist.
Occurs when trying to use IP Helper in an Active/Active
clustering deployment.
89265
On the Policy-Based Routing screen, BGP
routes are shown as “OSPF or RIP route.”
Occurs when viewing the comment settings for a BGP
route in the Network > Routing page. The comment
should show as “BGP route.”
89112
When a node is deleted from the
Active/Active Nodes table on the High
Availability page, the interface is not
deleted from the Network > Interfaces
page.
Occurs when deleting a node from the Active/Active
Nodes table and then viewing the Network > Interfaces
page. Workaround: Click the edit icon for the deleted
interface and then click OK. The interface will be
deleted.
89017
OSPF continues to advertise the Default
Route even after a WAN link failure due to
WAN Load Balancing logical probing.
Occurs when the option is enabled to advertise the
default route when the WAN is up, and WLB Probing is
enabled on the WAN. Upon a WAN link failure, OSPF
will still display the default route.
88371
Incorrectly configured routes prevent the
user from connecting to or pinging the
directly connected network.
Occurs when a preferences file is uploaded containing
custom routes in which the Destination network is
pointing to a LAN subnet and the Default Gateway is in
the same subnet, or the Destination firewall interface IP
address is routed to the Default Gateway IP address.
68413